Sign In | Join Free | My chinacomputerparts.com |
|
Brand Name : YSUN
Model Number : YS-3F
Certification : cULus:E509779/TUV:B1067040001/CQC:CQC21107292207
Place of Origin : China
MOQ : 100pcs
Price : negotiable
Payment Terms : T/T, Western Union, MoneyGram, L/C, D/A, D/P
Supply Ability : 500k per month
Delivery Time : 5-8 days
Packaging Details : standard or customization
Keyword : TRIAC Relays
Input voltage : 5/12/24VDC
Load voltage : 75-280VAC
Load current : 1A / 2A
Trigger mode : zero-cross / non zero-cross
Dielectric withstand voltage : 3000VAC
Mounting : PCB
Features : Dielectric strength 5000VAC
Overload Protection TRIAC Relays YS-3F New Energy Products Standard
TRIAC Relays Description:
The relay is an electrical control device, which can give a specified input quantity and keep it for a long enough time so that the controlled quantity will undergo a predetermined step change in the electrical output circuit. When the input volume drops to a certain level and maintains for a long enough time, it returns to the initial state.
TRIAC Relays Features:
1. Speed: It means that the protection device should be able to cut off the short-circuit fault as soon as possible. Its purpose is to improve system stability, reduce the damage of faulty equipment and lines, reduce the scope of faults, improve the effect of automatic reclosing and backup power supply or automatic input of backup equipment, etc.;
2. Sensitivity: When a metallic short circuit occurs within the protected range of equipment or lines, the protection device should have the necessary sensitivity coefficient. Guaranteed to be removed if there is a fault;
3. Selectivity: It means that the protection of the faulty equipment or the line itself should remove the fault first, and only when the protection of the faulty equipment or the line itself or the circuit breaker refuses to operate, the fault can be removed by the protection of the adjacent equipment, the line or the protection of the circuit breaker failure.
TRIAC Relays Technical Parameters:
Electric parameters(Environment temperature:25℃) | |||||||||||
Item | Symbol | Test condition | Min | Typical | Max | Unit | |||||
Input | LED Forward voltage | VF | IF=10mA |
| 1.16 | 1.3 | V | ||||
LED Reverse current | IR | VR=6V IF=0mA |
| 0.1 | 10 | μA | |||||
Output | Peak off-state current | IDRM | VDRM=600V |
|
| 100 | μA | ||||
Peak on-state voltage drop | VTM |
|
|
| 2.5 | V | |||||
Holding current | IH | IFTM=Max |
|
| 25 | mA | |||||
Rise rate off-state critical voltage | dv/dt | VDRM=600Vx1/√2 |
| 200 |
| V/μs | |||||
Transmission | LED trigger current | IFT | VD=6V RL=100Ω |
| 10 |
| mA | ||||
Turn-on time | Ton |
| 1 |
| 10 | ms | |||||
Turn-off time | Toff |
|
|
| 10 | ms | |||||
Insulation resistance | Riso | 500VDC(input-output) |
| 50 |
| GΩ | |||||
Weight |
|
|
|
| 0.58 |
| g |
TRIAC Relays Applications:
1. Traffic light system
2. Security systems
3. Computer peripheral interface
4. Remote system
![]() |
Overload Protection TRIAC Relays YS-3F New Energy Products Standard Images |